Factory wholesale Fungusclear™ Fungal Fluorescence Staining Solution - FOB Rapid Test – Liming Bio

Short Description:

REF 500210 Specification 96 Tests/Box
Detection principle Immunochromatographic assay Specimens Nasal/Oropharyngeal swab
Intended Use This is a rapid immunochromatographic assay for the detection of SARS-CoV-2 virus Nucleocapsid Protein antigen in human Nasal /Oropharyngeal swab collected from individuals who are suspected of COVID-19 by their healthcare provider within the first five days of the onset of symptoms. The assay is used as an aid in the diagnosis of COVID-19.


Product Detail

Product Tags

Related Video

Feedback (2)

We always follow the principle "Quality Very first, Prestige Supreme". We have been fully committed to delivering our customers with competitively priced high-quality products and solutions, prompt delivery and experienced services for Rare Candida Albicans, Trichomonas Vagunalis, Nucleic Acid Amplification Enzyme, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Factory wholesale Fungusclear™ Fungal Fluorescence Staining Solution - FOB Rapid Test – Liming Bio Detail:

FOB-Rapid-Test1

NTENDED USE
The StrongStep® FOB Rapid Test Strip (Feces) is a rapid visual immunoassay for the qualitative presumptive detection of human hemoglobin in human fecal specimens. This kit is intended to be used as an aid in the diagnosis of lower gastrointestinal (g.i.) pathologies.

INTRODUCTION
Colorectal cancer is one of the most commonly diagnosed cancers and a leading cause of cancer death in the United States. Screening for colorectal cancer probably increases the cancer detection at an early stage, therefore reduces the mortality.
Earlier commercially available FOB tests utilized the guaiac test, which requires special dietary restriction to minimize false positive and false negative results. The FOB Rapid Test Strip (Feces) are especially designed to detect human hemoglobin in fecal samples using Immunochemical methods, which improved specificity for the detection of lower gastrointestinal. disorders, including colorectal cancers and adenomas.

PRINCIPLE
The FOB Rapid Test Strip (Feces) has been designed to detect human hemoglobin through visual interpretation of color development in the internal strip. The membrane was immobilized with anti-human hemoglobin antibodies on the test region. During the test, the specimen is allowed to react with colored anti-human hemoglobin antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough human hemoglobin in specimens, a colored band will form at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.

PRECAUTIONS
■ For professional in vitro diagnostic use only.
■ Do not use after the expiration date indicated on the package. Do not use the test if the foil pouch is damaged. Do not reuse tests.
■ This kit contains products of animal origin. Certified knowledge of the origin and/or sanitary state of the animals does not completely guarantee the absence of transmissible pathogenic agents. It is therefore, recommended that these products be treated as potentially infectious, and handled by observing usual safety precautions (e.g., do not ingest or inhale).
■ Avoid cross-contamination of specimens by using a new specimen collection container for each specimen obtained.
■ Read the entire procedure carefully prior to testing.
■ Do not eat, drink or smoke in any area where specimens and kits are handled. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout the procedure and follow standard procedures for proper disposal of specimens. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.
■ The specimen dilution buffer contains sodium azide, which may react with lead or copper plumbing to form potentially explosive metal azides. When disposing of specimen dilution buffer or extracted samples, always flush with copious quantities of water to prevent azide buildup.
■ Do not interchange or mix reagents from different lots.
■ Humidity and temperature can adversely affect results.
■ Used testing materials should be discarded according to local regulations.

FOB Rapid Test3
FOB-Rapid-Test2

Instructions


Product detail pictures:

Factory wholesale Fungusclear™ Fungal Fluorescence Staining Solution - FOB Rapid Test – Liming Bio detail pictures


Related Product Guide:

Reliable quality and good credit standing are our principles, which will help us at a top-ranking position. Adhering to the tenet of "quality first, customer supreme" for Factory wholesale Fungusclear™ Fungal Fluorescence Staining Solution - FOB Rapid Test – Liming Bio , The product will supply to all over the world, such as: Latvia, Gabon, Nepal, We sincerely hope to cooperate with customers all over the world, if you would like to have more information, make sure you kindly contact us, we have been looking forward to building up a great business relationship with you.
  • We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Polly from Congo - 2018.06.19 10:42
    Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Maud from Swiss - 2017.08.16 13:39
    Write your message here and send it to us